The Communications CAD combines the calltaker, held and active calls, available units, notes, records queries, and operational tools.

Saving an unassigned event places it in Held Calls. Dispatching its first unit activates it. Notes, returns, and statuses remain in event history. When the final assigned unit clears an active event, BackdraftCAD closes it automatically.

Unit cancellation and channel lockdowns (DEV preview)​

Canceling a unit returns it to Available and returns an event with no remaining assignments to Held Calls. It does not close the event or add an entry to the event narrative. Clear remains the closing workflow. Held Calls identifies the last canceled handling unit when one exists.

The existing unit right-click menu retains its status and Watchdog controls and includes Cancel Unit from Event when the selected unit is attached to a call. Dispatchers can also use the command line: 123 X cancels one unit and 123, 456 X cancels multiple units. X never closes the event; C remains the distinct clear command.

Active dispatchers can open Channel Lockdown from CAD Operations. Its status table manages LAW and FIRE/EMS independently, with separate controls for activating or deactivating both. A persistent emergency-traffic banner appears in the affected MDT workspace. Activation starts with three fixed-pitch marker beeps, followed by one marker beep every 15 seconds while a relevant channel remains locked. Deactivation plays a five-second fixed-pitch release tone. Each workstation keeps its own mute and volume preference. Every state change records the dispatcher, channel, action, and time.